Ki sa ki se yon solisyon tanpon estanda pH? Ki karakteristik li yo?

Aug 01, 2023

Kite yon mesaj

Ki sa ki se yon solisyon tanpon estanda pH? Ki karakteristik li yo?

 

1. Ki sa ki se yon solisyon tanpon estanda pH? Ki karakteristik li yo?


Yon solisyon tanpon pH se yon solisyon ki ka kenbe yon valè pH ki estab. Si yon ti kantite asid oswa baz ajoute nan solisyon sa a, oswa yon reyaksyon chimik nan solisyon an pwodui yon ti kantite asid oswa baz, epi solisyon an se yon fason ki apwopriye dilye, valè pH solisyon an se fondamantalman ki estab epi ki pa chanje. Solisyon sa a ki ka reziste yon ti kantite asid oswa baz oswa gwo oswa ti dilution, epi kenbe valè pH la san chanjman yo rele yon solisyon tanpon.


Tanpon estanda pH la gen karakteristik sa yo:

(1) Valè pH solisyon Standard konnen epi li rive nan presizyon espesifye a;


(2) Valè pH solisyon Standard gen bon repwodiksyon ak estabilite, pi gwo kapasite tanpon, pi piti valè dilution ak pi piti koyefisyan tanperati;


(3) Metòd preparasyon solisyon an senp;


Ki jan yo prepare yon solisyon tanpon estanda pH?

Pou mezi jeneral pH, yon seri konplè reyaktif konpozisyon pH (kapab prepare 250mL) ka itilize. Lè w ap prepare solisyon an, yo ta dwe itilize dlo deyonize epi bouyi anvan pou 15-30 minit pou retire gaz kabonik ki fonn. Koupe sache plastik la, vide reyaktif la nan gode a, fonn li ak kantite dlo ki apwopriye deyonize, rense sak anbalaj la, vide l nan yon flakon volumetrik 250mL, delye li nan echèl la, epi souke li byen.


3. Ki jan yo byen estoke epi sèvi ak solisyon tanpon pH?

After preparing the buffer solution, it should be packed in a glass or polyethylene bottle (alkaline pH buffer solution, such as pH=9.18, pH=10.01, pH=12.46, etc., should be packed in a polyethylene bottle) with a tight lid. It should be stored in a refrigerator at low temperature (5-10 ℃) and can generally be used for about six months. If there is turbidity, mold, or precipitation in the existing mixer, it cannot be used again. When using, several 50mL polyethylene small bottles should be prepared, and the component solution from the large bottle should be poured into the small bottles. The bottles should be left at ambient temperature for 1-2 hours, and the temperature should be balanced before use. After use, it is not allowed to pour it into a large bottle to avoid contamination. The buffer solution in the bottle can be used for 2-3 days under environmental conditions>10 degre. Anjeneral, pH=7.00, pH=6.86, ak pH=14.00 ka itilize pou yon tan ki pi long. Solisyon pH=9.18 ak pH=10.01 absòbe gaz kabonik nan lè a, epi valè pH yo relativman fasil pou chanje.


Ki objektif yon 4. solisyon tanpon pH?

(1) Kalibre pH mèt la anvan mezi pH.


(2) Yo itilize li pou verifye presizyon pH-mèt la, pa egzanp, pH=6.86 ak pH=14.00. Apre kalibre pH-mèt la, mete elektwòd pH la nan solisyon pH=9.18 la, epi tcheke si valè enstriman an ki parèt an konsistan avèk valè pH solisyon Standard la.


(3) Tcheke si mèt pH la bezwen rekalibre pandan mezi presizyon jeneral. Apre kalibrasyon ak lè l sèvi avèk mèt pH la, ka gen derive oswa chanjman. Se poutèt sa, anvan tès la, mete elektwòd la nan yon solisyon tanpon estanda ki toupre solisyon an mezire, epi detèmine si rekalibrasyon nesesè ki baze sou grandè erè a.


(4) Tcheke pèfòmans elektwòd pH la.

 

2 Swim pool ph meter

Voye rechèch