Insert the test leads into the "COM" and "VΩ" holes, turn the knob to the desired range in "Ω", and connect the test leads to the metal parts at both ends of the resistor.

Avi:

1. If the measured resistance value exceeds the maximum value of the selected range, the over-range "1" will be displayed, and a higher range should be selected. For the resistance greater than 1MΩ or higher, it will take several seconds for the reading to stabilize. This is normal.

2. When not well connected, such as open circuit, the meter displays "1".

3. Lè w tcheke enpedans liy anba tès la, asire w ke ou retire tout ekipman pou pouvwa nan liy anba tès la epi dechaje tout kondansateur. Si gen ekipman pou pouvwa ak eleman depo enèji nan liy anba tès la, li pral afekte kòrèkteman tès enpedans liy lan.

4. The 200MΩ gear of the multimeter has 10 characters in short circuit. When measuring a resistance, these 10 characters should be subtracted from the measurement reading. For example, when measuring a resistance, it is displayed as 101.0, and 10 characters should be subtracted from 101.0. The actual resistance value of the measured component is 100.0 or 100MΩ.

5. Ou ka manyen rezistans nan ak men ou pandan mezi, men pa manyen tou de bout rezistans nan ak men ou an menm tan - kò imen an se yon kondiktè ak yon rezistans gwo men limite.


GVDA Digital Clamp meter GD118B: 

Pls Clink Below Photo and Read more details about this GVDA Digital Clamp mèt GD118B :

1